This consolidation is unoffical and is for reference only. For the official version of the regulations, consult the original documents on file with the Registry of Regulations, or refer to the Royal Gazette Part II. Regulations are amended frequently. Please check the list of Regulations by Act to see if there are any recent amendments to these regulations filed with the Registry that are not yet included in this consolidation. Although every effort has been made to ensure the accuracy of this electronic version, the Registry of Regulations assumes no responsibility for any discrepancies that may have resulted from reformatting. This electronic version is for your personal use and may not be copied for the purposes of resale in this or any other form.
Nova Scotia Offshore Area Petroleum Installations Regulations made under subsection 146(1) of the
Canada-Nova Scotia Offshore Petroleum Resources
Accord Implementation (Nova Scotia) Act
S.N.S. 1987, c. 3
O.I.C. 97-756 (December 9, 1997), N.S. Reg. 166/97Table of Contents
Text of regulations
Table of Contents
- Citation
- Interpretation
- Part I - General Requirements
- General
- Quality assurance
- Helicopter deck
- Facilities for inspection and maintenance
- Secondary structures and fittings
- Arrangements of materials and equipment
- Access to hazardous areas
- Ventilation of hazardous areas
- General electrical standards
- Emergency electrical power
- Mechanical equipment
- Winterization
- Corrosion protection
- Cranes
- Gas release system
- Emergency shutdown system
- Escape routes
- Protection against impact
- Navigational equipment
- Lifesaving equipment for installations
- Passive fire and blast protection
- Fire hydrant systems
- Water deluge and water monitor systems in areas with petroleum
- General requirements for fire pump systems and water mains
- Sprinkler system in accommodation areas
- Fire extinguishing systems in machinery and flammable liquid storage spaces
- Fire extinguishers
- Firefighting equipment
- Automatic fire detection systems
- Gas detection systems
- Alarm panels and signals
- General alarm system
- Piping systems
- Communication systems
- Part II - Analysis and Design
- General design considerations
- Design of installations
- Design of platforms
- Analyses
- Innovations for installations
- Removal and abandonment of fixed production installations
- Concept safety analysis for production installations
- Environmental criteria and loads
- Site investigations
- Geotechnical parameters
- Soil deformation
- Erosion offshore
- Materials for installations
- Air gap and freeboard
- Load measuring system
- Gravity-base, fill, fill-retention and self-elevating platforms
- Pile foundations
- Structural strength of mobile platforms
- Motion response characteristics
- Stability of mobile platforms
- Ballast and bilge systems
- Watertight integrity of floating platforms
- Mooring
- Dynamic positioning
- Subsea production systems
- Part III - Construction and Installation
- Part IV - Operations and Maintenance
- Manual, Plans and Programs for installations
- Repair, replacement and modification of installations
- Remedial action
- Part V - Records and Reporting
- Part VI - Offences
Citation
1 These regulations may be cited as the "Nova Scotia Offshore Area Petroleum Installations Regulations".Interpretation
2 (1) In these regulations,(a) "accidental event" means an unplanned or unexpected event or circumstance or series of events or circumstances that may lead to loss of life or damage to the environment;
(b) "accommodation area" means dependent personnel accommodation or an accommodation installation;
(c) "accommodation installation" means an installation that is used to accommodate persons at a production site or drill site and that functions independently of a production installation, drilling installation or diving installation, and includes any associated dependent diving system;
(d) "Act" means the Canada-Nova Scotia Offshore Petroleum Resources Accord Implementation (Nova Scotia) Act;
(e) "certificate of fitness" means a certificate, in the form fixed by the Board, issued by a certifying authority in accordance with Section 4 of the Nova Scotia Offshore Area Certificate of Fitness Regulations;
(f) "certifying authority" has the same meaning as in Section 2 of the Nova Scotia Offshore Area Certificate of Fitness Regulations;
(g) "Chief" means the Chief Safety Officer;
(h) "classification society" means an independent organization whose purpose is to supervise the construction, ongoing maintenance and any modifications of a platform in accordance with the society's rules for classing platforms and includes the American Bureau of Shipping, Lloyd's Register of Shipping, Det norske Veritas Classification A/S and Bureau Veritas;
(i) "contingency plan" means a plan that addresses abnormal conditions or emergencies that can reasonably be anticipated;
(j) "control point" means a work area other than a control station from which systems and equipment critical to the safety of the installation can be monitored and controlled;
(k) "control station" means a continuously manned work area from which process and export equipment, wellhead manifold and Christmas trees, main and emergency power, fire and gas detection, fire control, communications equipment, emergency shutdown systems, ballast control system, dynamic positioning systems and other systems and equipment critical to the safety of the installation are remotely controlled or monitored;
(l) "damaged condition" means, with respect to a floating platform, the condition of the platform after it has suffered damage to the extent described in the Code referred to in subsection 56(9);
(m) "dependent diving system" means a diving system that is associated with an installation other than a diving installation and that does not function independently of the installation;
(n) "dependent personnel accommodation" means personnel accommodation that is associated with an installation other than an accommodation installation and that does not function independently of the installation;
(o) "development plan" means a development plan relating to the development of a pool or field that is referred to in Section 136 of the Act;
(p) "development plan approval" means the approval of a development plan pursuant to Section 136 of the Act;
(q) "diving installation" means a diving system and any associated vessel that function independently of an accommodation installation, production installation or drilling installation;
(r) "Diving Program Authorization" means an authorization to conduct a diving program that is issued to an operator by the Board pursuant to clause 135(1)(b) of the Act;
(s) "diving system" means the plant or equipment used in or in connection with a diving operation, and includes the plant and equipment that are essential to a diver or to a pilot of a manned submersible;
(t) "drilling base" means the stable foundation on which a drilling rig is installed, and includes the ground surface, an artificial island, an ice platform, a platform fixed to the ground or seafloor and any other foundation specially constructed for drilling operations;
(u) "drilling installation" means a drilling unit or a drilling rig and its associated drilling base, and includes any associated dependent diving system;
(v) "Drilling Program Authorization" means an authorization to conduct a drilling program that is issued to a person by the Board pursuant to clause 135(1)(b) of the Act;
(w) "drilling rig" means the plant used to make a well by boring or other means, and includes a derrick, draw-works, rotary table, mud pump, blowout preventer, accumulator, choke manifold, dependent personnel accommodation and other associated equipment, including power, control and monitoring systems;
(x) "drilling unit" means a drillship, submersible, semi-submersible, barge, jack-up or other vessel that is used in a drilling program and is fitted with a drilling rig, and includes other facilities related to drilling and marine activities that are installed on a vessel or platform;
(y) "drill site" means a location where a drilling rig is or is proposed to be installed;
(z) "environmental load" means a load imposed by waves, currents, tides, wind, ice, sea ice, snow, an earthquake or any other naturally occurring phenomenon, or by any combination of those phenomena;
(aa) "floating platform" means a column-stabilized mobile platform or a surface mobile platform;
(ab) "flowline" means a pipeline that is used to transport fluids from a well to a production facility or vice versa, and includes intrafield export and all gathering lines;
(ac) "gastight door" means a solid, close-fitting door designed to resist the passage of gas under normal operating conditions;
(ad) "hazardous area" means an area classified as hazardous in the Recommended Practice referred to in subsection (2);
(ae) "installation" means a diving installation, a drilling installation, a production installation or an accommodation installation;
(af) "intact condition" means, with respect to a floating platform, that the platform is not in a damaged condition;
(ag) "machinery space" means a space on an installation where equipment incorporating rotating or reciprocating mechanical equipment in the form of an internal combustion engine, a gas turbine, an electric motor, a generator, a pump or a compressor is located;
(ah) "major damage" means damage that results in uncontrolled pollution or loss of or serious threat to life;
(ai) "manned installation" means an installation on which persons are normally present;
(aj) "marine activities" means activities related to position keeping and collision avoidance of mobile platforms, including mooring, dynamic positioning and ballasting;
(ak) "mobile platform" means a platform that is designed to operate in a floating or buoyant mode or that can be moved from place to place without major dismantling or modification, whether or not it has its own motive power;
(al) "new installation" means an installation that is constructed after the coming into force of these regulations;
(am) "non-combustible material" means material that does not burn or give off flammable vapours in sufficient quantity for self-ignition when heated to 750°C;
(an) "operating condition", with respect to a mobile platform, means the condition of operating at the operating draft;
(ao) "operating draft", with respect to a mobile platform, means the vertical distance in metres from the moulded base line to the assigned waterline, where the platform is operating under combined environmental and operational loads that are within the limits for which the platform was designed to operate;
(ap) "operations manual" means the manual referred to in Section 63;
(aq) "operator" means a person who has applied for or has been granted a production authorization, a Drilling Program Authorization or a Diving Program Authorization;
(ar) "platform" means a platform associated with an installation;
(as) "production facility" means equipment for the production of oil or gas located at a production site, including separation, treating and processing facilities, equipment and facilities used in support of production operations, landing areas, heliports, storage areas or tanks and dependent personnel accommodations, but not including any associated platform, artificial island, subsea production system, drilling equipment or diving system;
(at) "production installation" means a production facility and any associated platform, artificial island, subsea production system, offshore loading system, drilling equipment, facilities related to marine activities and dependent diving system;
(au) "production operation" means an operation that is related to the production of oil or gas from a pool or field;
(av) "production operations authorization" means an authorization to conduct production operations issued to an operator by the Board pursuant to clause 135(1)(b) of the Act;
(aw) "production site" means a location where a production installation is or is proposed to be installed;
(ax) "subsea production system" means equipment and structures that are located on or below or buried in the seafloor for the production of oil or gas from, or for the injection of fluids into, a field under a production site, and includes production risers, flow lines and associated production control systems;
(ay) "survival condition", with respect to a mobile platform, means the condition of the platform when it is subjected to the most severe environmental conditions determined pursuant to Section 44;
(az) "survival draft", with respect to a mobile platform, means the vertical distance in metres from the moulded baseline to the assigned waterline, where the platform is subjected to the most severe environmental conditions determined pursuant to Section 44;
(ba) "transit draft", with respect to a mobile platform, means the vertical distance in metres from the moulded base line to the assigned waterline, when the platform is moving from one geographical location to another;
(bb) "unmanned installation" means an installation on which persons are not normally present and in those instances when persons are present on the installation, their presence is for the purpose of performing operational duties, maintenance or inspections that will not necessitate an overnight stay;
(bc) "watertight" means designed and constructed to withstand a static head of water without any leakage;
(bd) "working area" means any area of an installation that a person may occupy during the normal course of duties, and includes a control room, workshop, machinery space, storage area and paint locker.
(2) Subject to subsection 9(2), for the purposes of Sections 10, 11, 13, 14, 19 and 33, the classification of hazardous areas with respect to hazards caused by combustible gases on an installation shall be made in accordance with American Petroleum Institute RP 500, Recommended Practice for Classification of Locations for Electrical Installations at Petroleum Facilities.
(3) A reference to a standard or specification shall be considered to be a reference to that standard or specification as amended from time to time.
Part I - General Requirements
General
3 For the purpose of ensuring the safety of an installation, no operator shall use the installation unless the equipment on the installation is arranged in accordance with these regulations to(a) provide for the safety of personnel;
(b) minimize damage to the environment; and
(c) enable easy access to the equipment.
Quality assurance
4 (1) Every new installation shall be designed, constructed, installed and commissioned in accordance with a quality assurance program that complies with subsection (2) and that is selected in accordance with Canadian Standards Association CAN3-Z299.0-86, Guide for Selecting and Implementing the CSA Z299 Quality Program Standards.(2) A quality assurance program shall be developed in accordance with
(a) Canadian Standards Association CAN3-Z299.l-85, Quality Assurance Program -- Category 1;
(b) Canadian Standards Association CAN3-Z299.2-85, Quality Control Program -- Category 2;
(c) Canadian Standards Association CAN3-Z299.3-85, Quality Verification Program -- Category 3; and
(d) Canadian Standards Association CAN3-Z299.4-85, Inspection Program -- Category 4.
Helicopter deck
5 (1) Every helicopter deck or facility that forms part of an installation shall(a) conform to Transport Canada TP 4414, Guidelines Respecting Helicopter Facilities on Ships; and
(b) be equipped so that any fuel stored on or adjacent to the helicopter deck or to the accommodation areas
(i) can be jettisoned by action taken at another location on the installation, or
(ii) is protected against damage or impact.
(2) Every helicopter deck that forms part of an installation shall be in a location that is readily accessible to and from the dependent personnel accommodation of the installation.
Facilities for inspection and maintenance
6 An installation shall be designed and equipped in such a manner as to allow for the monitoring, maintenance and periodic inspection of the installation, including(a) clear marking and identification of the areas to be inspected;
(b) provision for safe access to and adequate inspection space for the areas to be inspected;
(c) space for the storage and operation of diving equipment;
(d) means to facilitate the work of divers, where inspection by divers is required;
(e) means to assist maintenance personnel, including those doing underwater maintenance, to perform their work safely and effectively; and
(f) in the case of a mobile platform that is not intended to be periodically drydocked, means to facilitate on-location inspection of the hull.
Secondary structures and fittings
7 All decks, deckhouses, skids, modules and other structures located or installed on an installation shall be capable of withstanding all the loads and forces to which they will be subjected, as determined in accordance with Section 44.Arrangements of materials and equipment
8 (1) In this Section(a) "flame-type equipment" means any electric or fired heating equipment that uses an open flame, electric arc or element, and includes a space heater, a torch, a heated process vessel, a boiler, an electric arc or an open flame welder, or an open element electric heater or appliance;
(b) "process vessel" means a heater, dehydrator, separator, treater or vessel used in the processing or treatment of produced gas or oil.
(2) No person shall create or cause to be created any unprotected flame or source of ignition within 50 m of a well, an oil storage tank or other source of ignitable vapour.
(3) No flame-type equipment shall be placed or operated within 25 m of a well, an oil storage tank or other source of ignitable vapour, except
(a) where the well is
(i) a water supply well, or
(ii) a water injection well equipped with a suitable packer and with the surface casing annulus vented outside any building; or
(b) where emergency works requires the use of flame-type equipment and the wellhead valves and blow-out preventer, if any, are closed.
(4) No flame-type equipment shall be placed or operated within 25 m of a process vessel, unless the flame-type equipment is fitted with an adequate flame arrester.
(5) No flame-type equipment shall be located in the same building as a process vessel or other source of ignitable vapour, unless
(a) the air intakes and flues of all burners are located outside the building;
(b) relief valves, safety heads and other sources of ignitable vapours are vented outside the building and discharged above roof level; and
(c) the building is adequately cross-ventilated.
(6) All process vessels and equipment from which ignitable vapour may issue shall be vented to the atmosphere, and all vent lines from every storage tank that is vented to flare pits or flare stacks shall be provided with flame arresters or other equivalent safety devices.
(7) An exhaust pipe from an internal combustion engine located within 25 m of a well, a process vessel, an oil storage tank or other source of ignitable vapour shall be constructed so that
(a) any emergence of flame along its length or at its end is prevented; and
(b) the end is at least 6 m from the vertical centre line of the well projected upward and shall be directed away from the well.
(8) All equipment at or near a well, a process vessel, an oil storage tank or other source of ignitable vapour shall be constructed in accordance with Part I of the Canadian Electrical Code Part I and the Nova Scotia Offshore Area Oil and Gas Occupational Health and Safety Regulations.
Access to hazardous areas
9 (1) Subject to subsection (2), there shall not be direct access or any opening in an installation between(a) a non-hazardous area and a hazardous area; or
(b) a Class I, Division 2, hazardous area and a Class I, Division 1, hazardous area.
(2) Subject to subsections (3) to (5), an enclosed area that has direct access to, and that is classified as less hazardous than, a Class I, Division 1, hazardous area or a Class I, Division 2, hazardous area shall be considered to have the same classification as the area to which it has direct access.
(3) An enclosed area that has direct access to a Class I, Division 1, area shall be considered to be a Class I, Division 2, hazardous area if
(a) the access is fitted with a self-closing gastight door that opens into the enclosed area; and
(b) when the door is open, the air flows from the enclosed area into the Class I, Division 1, hazardous area.
(4) An enclosed area shall not be considered to be a hazardous area because of its direct access to a Class I, Division 2, hazardous area if
(a) the access is fitted with a self-closing gastight door that opens into the enclosed area; and
(b) when the door is open, the air flows from the enclosed area into the Class I, Division 2, hazardous area.
(5) An enclosed area shall not be considered to be a hazardous area because of its direct access to a Class I, Division 1, hazardous area if
(a) the access is fitted with self-closing gastight doors forming an air-lock; and
(b) the enclosed area is maintained at a pressure that is higher than the pressure maintained in the Class I, Division 1, hazardous area.
(6) Piping systems on an installation shall be designed to preclude direct communications between hazardous areas of different classifications and between hazardous and non-hazardous areas.
Ventilation of hazardous areas
10 (1) Every enclosed hazardous area on an installation shall be ventilated.(2) The ventilation systems fitted on an installation for the purpose of subsection (1) shall be capable of replacing the air in the hazardous area at the rate of once every five minutes.
(3) Where a mechanical ventilation system is used for the purpose of subsection (1), the air in the enclosed hazardous area shall be maintained at a pressure that is lower than the pressure of each adjacent hazardous area that is classified as less hazardous.
(4) All air let into an enclosed hazardous area shall be taken from a non-hazardous area, and where the inlet duct passes through a hazardous area classified as more hazardous than the one to which the duct leads, the air in the inlet duct shall be maintained at a pressure that is higher than the pressure of the air in the hazardous area through which it passes.
(5) All air let out of an enclosed hazardous area shall be let into an outdoor area that would be classified as the same as or less hazardous than the enclosed hazardous area if it did not receive the air from the enclosed hazardous area.
(6) The ventilation system for every non-hazardous area shall be separate from the ventilation system for every hazardous area, and the ventilation fan inlets and outlets shall be arranged to prevent the air from a hazardous area from moving, as a result of the operation of any fan or the wind, into an area classified as less hazardous.
(7) Every ventilation outlet duct leading from a non-hazardous area where drilling or production operations are conducted to a Class I, Division 2, hazardous area shall be equipped with self-closing shutters and a gas detector.
(8) A differential pressure gauge shall be installed to monitor any loss of ventilation pressure differential required by subsection (3) or (4) or maintained under Section 9, and to activate audible and visual alarms at the appropriate control point after a suitable period of delay not exceeding 30 seconds if a loss occurs.
(9) The control station and all accommodation areas on an installation shall
(a) be maintained at a positive overpressure relative to atmospheric pressure; and
(b) have airlock arrangements on all external doors.
(10) The power for a mechanical ventilation system provided in accommodation areas, working areas, flammable liquid storage areas and other hazardous locations of an installation shall be capable of being shut off from the control station and from a position that is outside the area being served by the ventilation system and that will remain accessible during any fire that may occur within the area being ventilated.
(11) The main inlets and outlets of all ventilation systems shall be capable of being closed from a position that is outside the area being served by the ventilation system and that will remain accessible during any fire that may occur within the area being ventilated.
General electrical standards
11 (1) Subject to subsections (2) to (4), all electric motors, lighting fixtures, electric wiring and other electrical equipment on an installation shall be designed, installed and maintained in accordance with the American Petroleum Institute RP l4F, Recommended Practice for Design and Installation of Electrical Systems for Offshore Production Platforms.(2) Electrical wiring on an installation shall be
(a) designed in accordance with International Electrotechnical Commission Publication 92-3, Electrical Installations in Ships, Part 3: Cables (construction, testing and installations) and tested for Category A in accordance with International Electrotechnical Commission Publication 332-3, Tests on electrical cables under fire conditions, Part 3: Tests on bunched wires or cables; and
(b) tested for impact at -35°C and bending at -40°C in accordance with Canadian Standards Association Standard C22.2 No. 0.3-M1985, Test Methods for Electrical Wires and Cables.
(3) Where a primary or secondary distribution system for power, heating or lighting, with no connection to earth, is used on an installation, a device capable of continuously monitoring the insulation level to earth and of giving an audible or visual indication of abnormally low insulation values shall be provided.
(4) The primary source of electrical power on every installation shall
(a) include at least two power plants;
(b) be capable of supporting all normal operations without recourse to the emergency source of electrical power required by Section 12; and
(c) if one of the power plants is out of operation, be capable of supporting all operations except drilling and production operations.
(5) The primary circuits from the power plant serving an installation shall be equipped with at least two manual shut-off switches, each at a different location.
Emergency electrical power
12 (1) Every installation shall have an emergency source of electrical power that is independent of the primary source of electrical power and that is capable of supplying electrical power sufficient to operate, for at least twenty-four hours, the following equipment:(a) all lights referred to in subsection (2);
(b) all gas detection and alarm systems;
(c) all fire detection and alarm systems;
(d) all firefighting systems except any fire pump that is driven by a liquid fuelled combustion engine;
(e) the general alarm system and all internal communication systems;
(f) the emergency shut-down system referred to in Section 18;
(g) all lifesaving systems;
(h) all navigation lights, sound signal systems and illuminated markings, that are required by Section 21;
(i) all radio communication equipment necessary to comply with the contingency plans referred to in Section 43;
(j) on a mobile platform, the main ballast control system, one ballast pump for each individual ballast system and one bilge pump for each individual bilge system;
(k) on a column-stabilized mobile platform, the secondary ballast control system;
(l) all equipment necessary to secure the production or drilling operations in progress at any one time in a safe manner, including a well disconnect system;
(m) if a pumping system is required under clause (l), one pump that is not driven by an internal combustion engine that has sufficient capacity to kill any well on the installation;
(n) any blow-out prevention system; and
(o) any manned diving equipment dependent on an electrical supply.
(2) Every installation shall be equipped with lights supplied by the emergency source of power described in subsection (1), in the following locations:
(a) every embarkation station on deck and over sides;
(b) every escape route and area containing escape route markings;
(c) all service corridors and corridors in accommodation areas, and all stairways, exits and personnel lift cars;
(d) all machinery spaces and main generating stations;
(e) the control station and all control points;
(f) all spaces from which the drilling and production operations are controlled and at which controls of machinery essential for the performance of those operations and devices for the emergency shutdown of the power plant are located;
(g) the stowage positions for firefighting equipment;
(h) each sprinkler pump and fire pump and each ballast and bilge pump, referred to in clause (1)(j), and the starting position for each pump;
(i) every helicopter landing deck and every obstacle marker on that deck; and
(j) the radio room.
(3) Where the emergency source of electrical power required by subsection (1) is a mechanically driven generator, the installation shall be provided with
(a) a transitional source of electrical power, unless the generator will automatically start and supply the power required by subsection (1) in less than 45 seconds from the time the primary source of electrical power fails; and
(b) a self-contained battery system designed to supply sufficient power, automatically on failure or shutdown of both the primary and the emergency sources of electrical power, to operate, for a period of at least one hour the equipment described in subclauses (i) and (ii) and, for a period of at least four days, the equipment described in subclause (iii):
(i) the lights located in every emergency exit route, at every escape route, in every machinery space, the control station and every emergency assembly room and at every launching station of the lifesaving system,
(ii) the internal communication system and the general alarm system, and
(iii) the navigation lights, sound signal systems and illuminated markings referred to in Section 21.
(4) The battery system referred to in clause (3)(b) shall be capable of returning to the trickle charge state on restoration of the primary or emergency source of electrical power.
(5) The emergency source of electrical power required by subsection (1) shall, for a floating platform, be designed to function at full rated power when the installation is upright and when it is at any inclination up to a maximum angle of
(a) 22 l/2 degrees about the longitudinal axis and 10 degrees about the transverse axis, in the case of a surface mobile platform;
(b) 25 degrees in any direction, in the case of a column-stabilized mobile platform; and
(c) 15 degrees in any direction, in the case of a self-elevating platform.
(6) The location of the emergency source of electrical power and associated fuel storage, the transitional source of power, if any, and the emergency switchboard on an installation shall be
(a) readily accessible from an open deck space;
(b) segregated by class A-60 divisions, as defined in subsection 23(1), from any space containing the main source of electrical power or the internal combustion engines;
(c) outside any hazardous area; and
(d) for a floating platform, located above the waterline that would exist if the platform were in a damaged condition and in a space outside any part of the platform if it were in that damaged condition.
(7) The emergency source of electrical power required by subsection (1) shall be designed to supply electrical power automatically, on failure of the primary source of electrical power, to a switchboard that is designed to direct the power to the equipment listed in that subsection.
Mechanical equipment
13 (1) Every internal combustion engine on an installation shall be installed, maintained and operated in accordance with American Petroleum Institute RP 7C-llF, Recommended Practice for Installation, Maintenance and Operation of Internal-Combustion Engines.(2) Combustion air for every internal combustion engine and fired vessel shall be taken from non-hazardous areas.
(3) Exhaust gas from every internal combustion engine and fired vessel shall be discharged to non-hazardous areas.
(4) The air induction system of every diesel engine operating in a hazardous area shall be equipped with
(a) a flame arrester in the induction system;
(b) a shut-off valve that is located between the engine air inlet filter and the induction system flame arrester and that is capable of being closed automatically by the engine overspeeding device and manually;
(c) a flame arrester in the exhaust system; and
(d) a spark arrester in the exhaust system, downstream of the flame arrester.
(5) Subject to subsection (13), the fuel supply system for every diesel engine shall be equipped with a manual shut-off device and, except for the emergency source of electrical power required by Section 12, with a device that will automatically shut off the fuel supply if any of the following occur:
(a) overspeeding;
(b) high exhaust temperature;
(c) high cooling water temperature; or
(d) low lubricating oil pressure.
(6) The engine crankcase breather pipe on every diesel engine shall
(a) be equipped with a flame arrester; and
(b) in the case of an engine in an enclosed Class I, Division 2, hazardous area, lead to the atmosphere outside the installation.
(7) Basic operating instructions for every diesel engine shall give details of stop, start and emergency procedures and be permanently attached to the engine.
(8) The layout of every gas turbine, including the location of the control points, shall take into account the ability of the control point closest to the turbine to withstand pressure waves in the event of an explosion in the gas turbine exhaust duct or gas turbine hall and the effects of the failure of a gas turbine rotor where the fragments cannot be contained.
(9) Every gas turbine shall have, in addition to the speed governor, a separate overspeed device, arranged and adjusted so that the manufacturer's overspeed limitations for the turbine cannot be exceeded by more than 15 per cent.
(10) The air intakes and exhaust for every gas turbine shall be arranged to prevent, to the extent practicable, reingestion of combustion gases.
(11) Every multi-engine gas turbine shall have a separate air intake and exhaust, arranged so as to prevent induced circulation through a stopped turbine.
(12) All machinery, components and systems essential to the operation of a floating platform shall be designed to function at full rated power at any inclination, up to a maximum angle of
(a) in the case of a surface mobile platform,
(i) 15 degrees in any direction under static conditions,
(ii) 22½ degrees in any direction under rolling dynamic conditions, and
(iii) 7½ degrees by bow or stern under rolling dynamic conditions;
(b) for a column-stabilized mobile platform, 15 degrees in any direction; and
(c) for a self-elevating platform, 10 degrees in any direction.
(13) The automatic shut-off device referred to in subsection (5) shall shut off the fuel supply to engines associated with fire pump systems only where overspeeding occurs.
(14) Jacking mechanisms for self-elevating platforms shall, where possible, be arranged with redundancy so that a single failure of any component does not cause an uncontrolled descent of the platform.
Winterization
14 (1) Every installation shall be designed, constructed, equipped and insulated to ensure that, at the minimum air temperature that may occur at the drill site or production site during operations, based on an annual probability of exceedance of 10-2,(a) in the case of a production installation, the production equipment and other associated equipment will operate in a safe and efficient manner;
(b) the emergency shutdown system referred to in Section 18 will perform its intended functions;
(c) drilling safety systems and associated equipment will operate in accordance with the Nova Scotia Offshore Area Petroleum Drilling Regulations;
(d) the fluids in the following systems and components will not freeze, namely,
(i) fresh water tanks and the associated piping,
(ii) vent pipes,
(iii) components of the drainage system,
(iv) the hydraulic system and its components, including operators and cylinders, and
(v) the firefighting system, including pump drives and fuel supply lines, fire pumps and associated piping, fire hydrants, fire hoses and nozzles;
(e) every pneumatic control system will remain fully operational at all times;
(f) the lifesaving appliances and associated devices will remain operational; and
(g) in the case of a mobile platform,
(i) the fluid in an operating ballast system, including the pumps, control systems and associated piping and valves, is protected against freezing,
(ii) the proper functioning of any thrusters is not impaired and the hydraulic fluid and lubricants for the thrusters have properties designed for such a temperature, and
(iii) the mooring winches and, where the platform is so equipped, the quick disconnect system will remain fully operational.
(2) Every installation shall be equipped with steam-generating equipment, or an equivalent means, that will keep the locations mentioned in subsection (3) free of ice and snow and lines thawed so as to permit drilling, production and maintenance operations to be conducted safely.
(3) Every installation that is equipped with steam-generating equipment, or an equivalent means, required by subsection (2) shall include outlets, hoses and hose clamps capable of being used in the following locations:
(a) work areas;
(b) walkways; and
(c) the helicopter deck and the lifeboat embarkation stations.
(4) Where temperatures below -20oC may occur, based on an annual probability of exceedance of 10-2, at the drill site or production site more than one day per year and where the installation is equipped with steam-generating equipment, or an equivalent means, required by subsection (2),
(a) that equipment shall meet the requirements set out in subsection (2) when operating at 75 per cent capacity; and
(b) the installation shall be equipped with a second set of steam-generating equipment or another means of providing equivalent protection against ice, snow and freezing.
Corrosion protection
15 (1) All structural elements that are part of an installation and the failure of which as a result of corrosion would cause a safety hazard shall be protected or constructed with extra material so as to prevent the degree of corrosion that may cause that structural element to fail and shall be protected against corrosion in accordance with Section 4.15 of Canadian Standards Association CAN/CSA-S471-92, General Requirements, Design Criteria, the Environment, and Loads.(2) Corrosion protection systems for installations shall be designed, installed and maintained in accordance with
(a) Section 15 of Canadian Standards Association CAN/CSA-S473-92, Steel Structures, Offshore Structures, in the case of steel platforms; and
(b) Sections 4.9.5, 5.1.1, 5.3, 5.4.2, 5.6, 5.10 and 11.19 of Canadian Standards Association Preliminary Standard S474-M1989, Concrete Structures, in the case of concrete platforms.
(3) All corrosion protection systems on an installation shall be designed so that adjustment, repair or replacement can be done on site, except where
(a) dry dock surveys are possible and are scheduled at a frequency of five years or less; or
(b) the corrosion protection system is a cathodic protection system that has a design life exceeding that of the installation.
Cranes
16 Every crane on an installation shall(a) be designed and constructed in accordance with American Petroleum Institute Spec 2C, Specification for Offshore Cranes; and
(b) be operated and maintained in accordance with American Petroleum Institute RP 2D, Recommended Practice for Operation and Maintenance of Offshore Cranes.
Gas release system
17 (1) In this Section, "gas release system" means a system for releasing gas and combustible liquid from an installation, and includes a flare system, a pressure relief system, a depressurizing system and a cold vent system.(2) Every gas release system shall be designed and located, taking into account the amount of combustibles to be released, the prevailing winds, the location of other equipment and facilities, including rigs, the dependent personnel accommodation, the air intake system, embarkation points, muster areas, the helicopter approaches and other factors affecting the safe, normal flaring or emergency release of the combustible liquid, gases or vapours, so that when the system is operating it will not damage the installation, other installations, the land or other platforms in the vicinity used for the exploration or exploitation of resources, or injure any person.
(3) Every gas release system shall be designed and installed in accordance with
(a) American Petroleum Institute RP 520, Recommended Practice for the Design and Installation of Pressure-Relieving Systems in Refineries;
(b) American Petroleum Institute RP 521, Guide for Pressure-Relieving and Depressuring Systems;
(c) American Petroleum Institute Standard 526, Flanged Steel Safety-Relief Valves;
(d) American Petroleum Institute Standard 527, Seat Tightness of Pressure Relief Valves; and
(e) American Petroleum Institute Standard 2000, Venting Atmospheric and Low-Pressure Storage Tanks.
(4) Every gas release system shall be designed and constructed to ensure that oxygen cannot enter the system during normal operation.
(5) Any flare boom and its associated equipment shall be designed
(a) to ensure a continuous flame using an automatic igniter system;
(b) to withstand the radiated heat at the maximum venting rate;
(c) to prevent flashback; and
(d) to withstand all loads to which they may be subjected.
(6) Every gas release system shall be designed to limit to the acceptable levels permitted by the Nova Scotia Offshore Area Oil and Gas Occupational Safety and Health Regulations the noise that may occur as the gas expands.
(7) With the exception of water, any liquid that cannot be safely and reliably burned at the flare tip of a gas release system shall be removed from the gas before it enters the flare.
(8) Any vent that is used to release gas to the atmosphere without combustion shall be located and designed to minimize the risk of accidental ignition of the gas.
(9) Every gas release system shall be designed and installed so that, taking into account the prevailing wind conditions, the maximum radiation on areas where personnel may be located, from the automatically ignited flame of a flare or vent, will be
(a) 6.3 kW/m2, where the period of exposure will not be greater than one minute;
(b) 4.72 kW/m2, where the period of exposure will be greater than one minute but not greater than one hour; and
(c) l.9 kW/m2, where the period of exposure will be greater than one hour.
Emergency shutdown system
18 (1) Every installation shall have an emergency shutdown system that is capable of shutting down and isolating all potential sources of ignition and sources of flammable liquids or gases.(2) An emergency shutdown system shall be designed and installed so that when activated it causes
(a) an audible and visual signal that indicates the cause of its activation and the identity of the equipment that has been shut down and isolated to be given in the appropriate control point; and
(b) an audible alarm to be sounded through the general alarm system required by Section 34 unless the alarm is overridden by the control point operator.
(3) In the case of a production installation, an emergency shutdown system shall be designed to ensure
(a) that there are at least two levels of shutdown; and
(b) subject to subsection (13), that the following will occur within the time and in the sequence set out in the operations manual, namely,
(i) the shutdown of all production facilities and associated test facilities,
(ii) the closure of all surface inlet manifold safety valves and production riser safety valves,
(iii) the closure of all Christmas tree safety valves and all downhole safety valves, and
(iv) the shutdown of all utilities except the equipment listed in subsection 12(1).
(4) In the case of a production installation, manual operation of an emergency shutdown system shall be in accordance with American Petroleum Institute RP 14C, Recommended Practice for Analysis, Design, Installation and Testing of Basic Surface Safety Systems for Offshore Production Platforms.
(5) In the case of a drilling installation, an emergency shutdown system shall be designed to ensure
(a) the shutdown within the time and in the sequence set out in the operations manual of all utilities, except the equipment listed in subsection 12(1); and
(b) that shutdown is possible from at least two strategic locations.
(6) The emergency shutdown system shall be designed to permit the selective shutdown of the ventilation systems required by Section 10, except the fans necessary for supplying combustion air to prime movers for the production of electrical power.
(7) At least one of the controls of the emergency shutdown system shall be located outside hazardous areas.
(8) After an emergency shutdown, the emergency shutdown system shall stay in a locked-out condition until it is manually reset.
(9) The emergency shutdown system shall be connected to a source of power in such a way that, in the event of a failure of the primary source of power, there is automatic changeover to an emergency source of power and audible and visual alarms indicating that failure are given at the appropriate control point.
(10) Where a hydraulic or pneumatic accumulator is used to operate any part of the emergency system, the accumulator shall
(a) be located as close as is practicable to the part that it is designed to operate, except where that part is part of a subsea production system; and
(b) have capacity for at least three operations.
(11) In the event of a failure of the accumulator referred to in subsection (10), the shutdown valves shall revert to a fail-safe mode.
(12) All cables and pneumatic and hydraulic power lines that are part of the emergency shutdown system shall
(a) in the case of cables and power lines that are exposed to the risk of mechanical or fire damage, be protected
(i) by metal channels or casings, or
(ii) by being enclosed in a steel conduit or an equivalent covering; and
(b) as far as practicable, be segregated or routed away from the process and utility control systems so that any damage to those systems does not affect the shutdown system.
(13) In the case of a production installation, on activation of the emergency shutdown system, the surface-controlled subsurface safety valve shall close in not more than two minutes after the Christmas tree safety valve has closed, except where a longer delay is justified by the mechanical or production characteristics of the well.
Escape routes
19 On every manned installation,(a) every work area shall have at least two well-marked separate escape routes that are situated as far apart as is practicable;
(b) all escape routes shall lead to the open deck and from there to an evacuation station;
(c) in addition to the escape routes required by clause (a), clear passage shall be provided, where practicable, to the helicopter deck and sea level and other embarkation locations;
(d) all corridors that are more than 5 m long, all accommodation areas and, where practicable, all work areas shall have at least two exits, located as far apart as is practicable, that lead to escape routes;
(e) every escape route and embarkation station shall be free of all obstructions, and each exit door along the route shall be a sliding door or designed to open outwards;
(f) every escape route leading to an upper level shall, where practicable, be provided in the form of ramps or stairways;
(g) every escape route leading to a lower level shall, where practicable, be provided in the form of ramps, stairways or chutes of sufficient width to accommodate stretcher bearers with stretchers;
(h) suitable means shall be provided, where practicable, for persons to descend from the installation to the water;
(i) materials used for escape routes shall have a level of fire durability equivalent to steel;
(j) the survival craft evacuation stations located adjacent to the accommodation areas and the associated escape routes from the accommodation areas shall provide fire protection for a period of at least two hours; and
(k) all escape routes and associated stairwells shall be appropriately sheltered from the effects of fire and explosion.
Protection against impact
20 (1) Subject to subsection (4), every platform shall be designed to withstand accidental impacts with a vessel.(2) Where practicable, every platform shall have a fender system, buoyage system or similar arrangement that will permit the transfer of goods to and from the production installation and a vessel without endangering that production installation or vessel or any person or goods.
(3) Subject to subsection (4), every platform, including any fender system, shall be capable of absorbing the impact energy of not less than 4 MJ from a vessel without endangering any person or the environment.
(4) Subsections (1) and (3) do not apply to an unmanned platform if any impact described by those subsections will not cause major damage.
(5)
Every platform shall be designed so that the impact energy referred to in subsection (3)(a) can be totally absorbed in the permanent deformation of the structural element impacted and by the elastic deflection of the platform; and(b) will not be absorbed in the permanent deformation of the vessel.
(6) Where a fender system is used to comply with subsection (2), its size and arrangement shall be such that a vessel cannot be trapped under it at low tide.
Navigational equipment
21 Every installation shall be equipped with the navigation lights and sound signal systems that are required by,(a) in the case of a mobile platform, the Collision Regulations (Canada), as if the installation were a Canadian vessel; or
(b) in the case of a fixed platform, Sections 8, 9 and 10 of the Navigable Waters Works Regulations (Canada), as if the installation were in waters to which those regulations apply.
Lifesaving equipment for installations
22 (1) Every installation shall be provided with(a) subject to subsection (2), in the case of a manned installation, two or more totally enclosed survival craft that have a combined carrying capacity of at least 200 per cent of the total number of persons on board the installation at any one time, and in the case of an unmanned installation, one or more totally enclosed survival craft that have a combined carrying capacity of at least 100 per cent of the total number of persons on board the installation at any one time;
(b) one or more inflatable liferafts, that have a combined capacity for accommodating at least 100 per cent of the total number of persons on board the installation at any one time, and that
(i) meet the requirements for inflatable liferafts set out in Schedule XI to the Life Saving Equipment Regulations (Canada), as if the liferafts were in waters to which those regulations apply,
(ii) have float free capability,
(iii) if embarkation is more than 4.5 m from the waterline at the survival draft, are equipped with a launching device, and
(iv) are equipped with Class A equipment as described in Schedule II to the Life Saving Equipment Regulations (Canada);
(c) in the case of a manned installation, immersion suits for 200 per cent of the total number of persons on board the installation at any one time, that conform to National Standard of Canada CAN/CGSB-65.16-M89, Marine Abandonment Immersion Suit Systems, and that are stowed such that one suit is readily available adjacent to each bed and the remaining suits are equally distributed among evacuation stations;
(d) in the case of an unmanned installation, immersion suits for 100 per cent of the total number of persons on board the installation at any one time, that conform to the National Standard of Canada CAN/CGSB-65.16-M89, Marine Abandonment Immersion Suit Systems, and that are equally distributed among evacuation stations;
(e) a lifejacket for each of the persons on board the installation at any one time; and
(f) in the case of a manned installation,
(i) a motor-propelled rescue boat that
(A) meets the requirements for rescue boats set out in Regulation 47 of Chapter III of International Maritime Organization International Conference on Safety of Life at Sea,
(B) is located under a device capable of launching and retrieving the boat when the boat is fully loaded with equipment and complement, and
(C) is self-righting,
(ii) lifebuoys that are distributed on the decks of the installation, and that are stowed in a bracket or cleats, in at least the following numbers, namely,
(A) 8 lifebuoys for an installation that is 100 m or less in length,
(B) 10 lifebuoys for an installation that is more than 100 m but less than 150 m in length,
(C) 12 lifebuoys for an installation that is 150 m or more but less than 200 m in length, and
(D) 14 lifebuoys for an installation that is 200 m or more in length,
(iii) a rescue basket capable of accommodating at least six persons,
(iv) 12 Type A distress signals, as defined in the Life Saving Equipment (Canada) Regulations,
(v) a Class I emergency position indicator radio beacon, as defined in the EPIRB Regulations (Canada), in each control station,
(vi) at least two radar transponders stowed in two widely separated locations, except in the case of surface mobile platforms,
(vii) in the case of surface mobile platforms, at least one radar transponder, and
(viii) two buoyant personnel transfer baskets.
(2) Each of the totally enclosed survival craft provided on an installation shall
(a) meet the requirements for Class I lifeboats as set out in Schedule V to the Life Saving Equipment Regulations (Canada), as if the survival craft were in waters to which those regulations apply;
(b) be equipped with
(i) a compression ignition engine with two independent starting methods and with sufficient power to propel the craft when fully loaded,
(ii) an engine block heater, a head bolt heater or any other means of ensuring prompt engine start in cold weather,
(iii) a two-way fixed radio capable of permitting communications with other survival, support and rescue craft,
(iv) a towing attachment,
(v) the equipment required by Schedule I to the Life Saving Equipment Regulations (Canada), as if the installation were a Class I ship to which those regulations apply,
(vi) a launching device,
(vii) a radar reflector,
(viii) a Class II emergency position indicator radio beacon, as defined in the EPIRB Regulations (Canada), and
(ix) a hand-held radio;
(c) be self-righting;
(d) be fire-protected;
(e) be capable of a speed of not less than 6 knots;
(f) have a self-contained air supply sufficient for at least 10 minutes;
(g) be stored or equipped
(i) in the case of a column-stabilized mobile platform and a fixed platform, so as to launch in a bow out aspect, and
(ii) in the case of a self-elevating mobile platform, so as to clear each leg, column, footing, brace or mat and any other similar structure below the hull;
(h) be positioned so that half the survival craft are close to the accommodation areas and the other half are appropriately located on the other side of the installation, taking into consideration the shape of the installation and the type of associated facilities;
(i) be stowed in a secure and sheltered position that is protected from damage by fire or explosion; and
(j) be stowed in such a manner that two crew members can carry out preparations for embarkation and launching in less than 5 minutes.
(3) The launching devices for the totally enclosed survival craft, the rescue boat and the inflatable liferafts provided on an installation shall
(a) meet the requirements for launching devices set out in Schedule IX to the Life Saving Equipment Regulations (Canada), as if the launching devices were located in waters to which those regulations apply;
(b) be sufficiently strong to permit each survival craft, rescue boat or liferaft to be safely launched or lowered into the water when loaded with its full complement of persons and equipment; and
(c) situated so as to permit each survival craft, rescue boat or liferaft to be launched clear of any obstruction resulting from damage of the extent described in the Code referred to in subsection 56(9).
(4) Half of the lifebuoys provided on an installation shall be equipped with self-igniting lights, and not fewer than two of those lifebuoys shall be equipped with self-activating smoke signals.
(5) Two lifebuoys provided on an installation not equipped with lights and smoke signals shall be fitted with a buoyant lifeline, the length of which shall be at least one-and-a-half times the distance from the stowage deck to the waterline at the transit draft, or 30 m, whichever is greater.
(6) There shall be posted on every installation, including in the control station and in each accommodation area and work area, copies of a plan showing the position of all the lifesaving appliances.
Passive fire and blast protection
23 (1) In this Section,(a) "class A-0 division" means a division formed by a bulkhead or deck that is constructed
(i) of steel or an equivalent material and suitably stiffened, and
(ii) to prevent the passage of smoke and flame after 60 minutes of exposure to a standard fire test;
(b) "class A-60 division" means a division formed by a bulkhead or deck that is
(i) constructed of steel or an equivalent material and suitably stiffened,
(ii) constructed to prevent the passage of smoke and flame after 60 minutes of exposure to a standard fire test, and
(iii) insulated with non-combustible materials so that, if either side is exposed to a standard fire test, after 60 minutes the average temperature on the unexposed face will not increase by more than 139°C above the initial temperature and the temperature at any point on the unexposed face, including any joint, will not increase by more than 180°C above the initial temperature;
(c) "class B-15 division" means a division formed by a bulkhead, ceiling or lining that is
(i) constructed and erected entirely from non-combustible materials,
(ii) constructed to prevent the passage of flame after exposure to a standard fire test for 30 minutes, and
(iii) insulated so that if either face is exposed to the first 30 minute period of a standard fire test, the average temperature on the unexposed face will not increase at any time during the first 15 minutes of the test by more than 139°C above that initial temperature, and the temperature at any point on the unexposed face, including any joint, will not increase by more than 225°C above the initial temperature after exposure for 15 minutes;
(d) "class H-120 division" means a division formed by a bulkhead or deck that is
(i) constructed of steel or an equivalent material and suitably stiffened,
(ii) constructed to prevent the passage of smoke and flame after exposure to a hydrocarbon fire test for 120 minutes, and
(iii) insulated with non-combustible material so that, if either face is exposed to a hydrocarbon fire test, after 120 minutes the average temperature on the unexposed face will not increase by more than 139°C above the initial temperature, and the temperature at any point on the unexposed face, including any joint, will not increase by more than 180°C above the initial temperature;
(e) "hydrocarbon fire test" means a test in which a specimen division, which division resembles as closely as possible the intended construction of the division, includes, where appropriate, at least one joint and has an exposed surface of not less than 4.65 m2 and a height or a length of not less than 2.44 m, and is exposed in a test furnace to temperatures corresponding approximately to a time-temperature relationship defined by a smooth curve drawn through the following temperature points measured above the initial furnace temperature, namely,
(i) at the end of the first 3 minutes, 880°C,
(ii) at the end of the first 5 minutes, 945°C,
(iii) at the end of the first 10 minutes, 1032°C,
(iv) at the end of the first 15 minutes, 1071°C,
(v) at the end of the first 30 minutes, 1098°C,
(vi) at the end of the first 60 minutes, 1100°C, and
(vii) at the end of the first 120 minutes, 1100°C;
(f) "low flame spread" in respect of a surface, means that the surface restricts the spread of flame;
(g) "standard fire test" means a test conducted in accordance with Regulation 3.2 of Chapter II-2 of International Maritime Organization International Conference on Safety of Life at Sea.
(2) Subject to subsection (3), on an installation,
(a) the wellhead and process areas on a production installation shall be separated from other areas by class H-120 divisions;
(b) all control stations shall be separated from other areas by class A-60 divisions;
(c) the accommodation areas shall be separated from other areas by class A-60 divisions;
(d) every machinery space and every storeroom containing paint, oil, any gaseous substance or other flammable material shall be separated from galleys or accommodation areas by class A- 60 divisions and from each other by class A-0 divisions;
(e) galley supply and exhaust ventilator trunking within the accommodation areas or any other enclosed spaces shall be made of steel covered with a fire-resistant insulation material of a type and thickness equivalent to that in a class A-60 division;
(f) every deck and its supporting structure within the accommodation areas that is not required to be a class A-60 division shall be constructed of material that by itself or due to insulation provided will not lose its structural stability and fire integrity when subjected to a 60 minute standard fire test;
(g) every corridor bulkhead that is not required to be a class A-60 division shall be a class B- 15 division and extend from deck to deck or, when continuous class B-15 divisions that are ceilings are fitted, from the deck to the continuous ceiling;
(h) every door in every class B-15 division that is a bulkhead shall meet the standard for a class B-15 division, except that a door to a cabin or to a public space other than a stairway may have ventilation openings or a louvre in the lower half;
(i) no door of a division forming any part of a stairway enclosure shall be provided with ventilation openings or louvres;
(j) every opening in every bulkhead and deck in the accommodation areas shall have permanently attached to it a means of closing that will maintain the fire integrity of the bulkheads and decks;
(k) where a class A-0 division, class A-60 division, class B-15 division or class H-120 division is pierced for the passage of electric cables, pipes, trunks or structural elements or for other purposes, arrangements shall be made so that the fire resistance of the division is not impaired;
(l) air spaces enclosed behind ceilings, panelling or linings shall be divided by close-fitting draught stops that are spaced not more than 14 m apart and that are fitted transversely if the length of the space exceeds 14 m and lengthwise if the width exceeds 14 m;
(m) every internal stairwell, ladderwell and crew elevator trunk within the accommodation areas shall be constructed of steel or equivalent material;
(n) every stairwell in the accommodation areas shall be enclosed within a trunk constructed of class A-60 divisions and shall have self-closing doors, except that a stairwell connecting only two decks need only be fitted at one deck level with a division that has the same fire integrity and structural stability as the deck and self-closing doors;
(o) for compartments that contain or are affected by oil and oil vapour, the surface of insulating materials fitted to the inside of bulkheads and decks and forming the casings and crowns shall be impervious to oil and oil vapour;
(p) every door and shutter in a bulkhead opening to hatches in the galley and pantry shall be constructed so that the fire integrity of the bulkhead is maintained, and shall be capable of being readily closed from a position outside the galley or pantry;
(q) primary deck coverings shall be of a type that will not readily ignite;
(r) paints, veneers and other finishes used on surfaces on concealed or inaccessible spaces and on exposed surfaces, except furniture, furnishings and floor coverings, shall be such that the surfaces are of a low flame spread type;
(s) overboard scuppers, sanitary discharges or other outlets close to the water shall be of material unlikely to fail in the event of fire;
(t) every load-bearing steel structural element shall be fire protected; and
(u) blast-resistant panels and explosion venting systems shall be provided in locations that are susceptible to an explosion.
(3) Subsection (2) does not apply to an unmanned installation, if the passive fire and blast structural protection provided will prevent major damage in the case of a fire or explosion.
(4) Galleys on an installation shall be provided with fire blankets.
(5) Notwithstanding subsections (2) to (4), every installation shall be arranged in such a way that a fire in one area on the installation will be prevented from spreading to other areas and the consequences of an explosion on the installation are minimized, taking into account the fire or explosion hazard of any particular area.
Fire hydrant systems
24 (1) Every manned installation shall be provided with a fire hydrant system in accordance with this Section.(2) The fire hydrant system shall be connected to a continuously pressurized wet pipe water main that
(a) is connected to at least two pump systems that are situated as far apart as possible; and
(b) when any one of the pump systems required by clause (a) is out of operation,
(i) is capable of delivering at least one jet simultaneously from each of any two fire hydrants through the hoses and nozzles, at a pressure at the hydrants of at least 350 kPa,
(ii) is capable of delivering water at a sufficient pressure and quantity so that the aggregate capacity of the pump systems that are still operating is not less than 120 m3/hour when the pump systems are delivering water to the fire hydrants, and
(iii) is capable of maintaining a pressure of at least 700 kPa to any foam system protecting the helicopter deck.
(3) The number and position of the fire hydrants in the fire hydrant system shall be such that water from any two hydrants, one of which is fitted with only a single length of fire hose and the other of which is fitted with one or two lengths of fire hose, can reach every part of the installation where a fire may occur.
(4) Each fire hydrant in the fire hydrant system shall be provided with a hose that
(a) is of not more than 18 m in length;
(b) is equipped with a 19 mm dual purpose nozzle capable of spray or jet action and with the necessary couplings; and
(c) meets the requirements of National Fire Protection Association 1961, Standard on Fire Hose.
Water deluge and water monitor systems in areas with petroleum
25 (1) In this Section,(a) "water deluge system" means a system capable of deluging a space with water from fixed heads;
(b) "water monitor system" means a system capable of deluging a space with water from monitors.
(2) Every manned production installation shall be equipped with a water deluge system or, in the case of an open space, a water monitor system, for each space in the installation that contains equipment that stores, conveys or processes petroleum not used as fuel on the installation.
(3) The systems required by subsection (2) shall be
(a) connected to a continuously pressurized water main that is connected to at least two pump systems; and
(b) capable of discharging water at the rate of at least 12.2 L/minute/m² over the largest area served by the system when any one of the pump systems is out of operation.
(4) Every water deluge system shall
(a) operate automatically in response to a signal from the fire detection system;
(b) be capable of being operated manually from the control station and from locations close to but outside of each space served by it; and
(c) when in operation, automatically activate an audible and visual signal at the fire and gas indicator panel in the control station.
(5) Every water monitor system shall
(a) be capable of being activated manually from the control station and from locations close to but outside of each space served by it;
(b) have sufficient movement in the horizontal and vertical planes to permit the monitor to discharge water into any part of the space served by it;
(c) be capable of being locked in any position; and
(d) be capable of discharging water as a jet or spray.
(6) A water deluge system provided pursuant to subsection (2) shall meet the requirements of National Fire Protection Association 15, Standard for Water Spray Fixed Systems for Fire Protection.
General requirements for fire pump systems and water mains
26 (1) The fire hydrant system referred to in Section 24 and a water deluge system referred to in Section 25 may be connected to the same water main and main pump systems.(2) Every water main referred to in Section 24 or 25 shall
(a) be routed clear of hazardous areas as far as practicable;
(b) be arranged in relation to any thermal barriers and structural elements of the installation so as to obtain the maximum protection from damage due to heat;
(c) be equipped with valves that will permit a damaged part of the system to be isolated from the undamaged parts; and
(d) be used solely for the purpose of firefighting.
(3) Every sea suction and source of power for each of the pump systems referred to in Section 24 or 25 shall
(a) be designed and arranged to start automatically in response to
(i) any drop in water pressure that indicates a demand on the system,
(ii) the receipt of a signal from the fire detection system, and
(iii) the receipt of a signal from any manual control point;
(b) be capable of being started manually from the control station and started and stopped manually from a location close to the pump system;
(c) be capable of functioning continuously without attendance for at least 24 hours; and
(d) be designed and arranged so that a fire, explosion or flooding in any one space of the installation will not put more than one pump system out of operation.
(4) When any of the pump systems referred to in Section 24 or 25 is started, an audible alarm shall be given automatically at the pump and an audible and visual alarm shall be given automatically at the fire and gas indicator panel in the control station.
(5) Every pump system provided pursuant to Section 24 or 25 shall be located in a part of the installation remote from spaces that contain equipment used for storing, conveying or processing petroleum that is not used as fuel on the installation.
Sprinkler system in accommodation areas
27 (1) The accommodation areas in every manned installation shall be equipped with a sprinkler system that is supplied with water from(a) two dedicated pump systems connected to the water main referred to in Section 24 or 25 by way of a lockable screwdown non-return valve that will prevent backflow from the sprinkler system to the water main; or
(b) one dedicated sprinkler pump connected to
(i) the water main referred to in Section 24 or 25 by way of a lockable screwdown non-return valve that will prevent backflow from the sprinkler system to the water main, and
(ii) a pressurized fresh water tank having a volume equal to at least twice the volume of water required pursuant to subsection (2) to be supplied for a period of one minute.
(2) The volume of water supplied by the pump systems or pump and fresh water tank described in subsection (1) shall be at a pressure sufficient to ensure, at the level of the highest sprinkler, continuous coverage of at least 280 m2 at the rate of at least 6 L/minute/m2.
(3) The sprinkler pump required by clause (1)(b) shall
(a) serve only the sprinkler system;
(b) be activated automatically by a pressure drop in the system before the water in the fresh water tank is depleted; and
(c) be powered from at least two sources.
(4) When the sprinkler system is activated, an audible and visual alarm that shows the location of the activated sprinklers shall be given automatically at the fire and gas indicator panel in the control station.
(5) The sprinkler system shall be designed to prevent the passage of sea water into the fresh water tank.
(6) The sprinkler system shall be provided with at least one stop valve for every 200 sprinklers that can prevent the flow of water into those sprinklers without affecting the rest of the system.
(7) Each of the stop valves provided pursuant to subsection (6) shall be protected from accidental operation.
(8) A gauge indicating the pressure in the sprinkler system shall be fitted at each stop valve and at the control station.
(9) The sprinkler heads shall be placed in positions and spaced in a pattern that will ensure an average application rate of 6 L/minute/m2 throughout each space in the accommodation areas.
(10) The pump system or pump and fresh water tank required by subsection (1) shall be situated outside the accommodation areas and as far as possible from the main machinery space.
(11) The sprinkler system shall be
(a) installed in accordance with National Fire Protection Association 13, Standard for the Installation of Sprinkler Systems; and
(b) tested and maintained in accordance with National Fire Protection Association 13A, Recommended Practice for the Inspection, Testing and Maintenance of Sprinkler Systems.
Fire extinguishing systems in machinery and flammable liquid storage spaces
28 (1) On every installation, a fixed fire-extinguishing system utilizing carbon dioxide, pressure water spray or, where a fire will not involve any gases, liquefied gases with a boiling point below ambient temperature or cryogenic liquids, high expansion foam shall be installed in every space containing(a) internal combustion machinery having an aggregate power of at least 750 kW;
(b) an oil- or gas-fired boiler or any other fired process vessel having a thermal rating of at least 75 kW;
(c) paint or other flammable liquids as defined by National Fire Protection Association 321, Standard on Basic Classification of Flammable and Combustible Liquids; or
(d) mud pits or equipment used for removing drill solids where oil-based mud is used.
(2) On every installation, a fixed fire-extinguishing system utilizing carbon dioxide or pressure water spray shall be provided in every compartment containing a pump for the transfer of oil.
(3) A fire-extinguishing system utilizing carbon dioxide referred to in subsection (1) or (2) shall meet the requirements of National Fire Protection Association 12, Standard on Carbon Dioxide Extinguishing Systems.
(4) A fire-extinguishing system utilizing pressure water spray referred to in subsection (1) or (2) shall meet the requirements of National Fire Protection Association 15, Standard for Water Spray Fixed Systems for Fire Protection.
(5) A fire-extinguishing system utilizing high expansion foam referred to in subsection (1) shall meet the requirements of National Fire Protection Association 16, Standard on Deluge Foam-Water Sprinkler and Foam-Water Spray Systems.
(6) When a fire-extinguishing system utilizing carbon dioxide is provided pursuant to subsection (1) or (2), means shall be provided to
(a) stop all ventilation fans serving the space protected by that system automatically before the system is activated; and
(b) close all dampers in the ventilation system serving the space protected by that system manually from a position that is outside that space and that will not be made inaccessible by a fire within that space.
(7) Every fire-extinguishing system referred to in subsection (1) or (2) shall be capable of being activated manually
(a) from a location close to but outside each space served by it; and
(b) at the location where the extinguishing medium is stored.
(8) At each access to every space served by a fire-extinguishing system referred to in subsection (1) or (2) there shall be a notice indicating that the space contains such a system and stating which fire extinguishing medium is used.
(9) Visual indication of the operational status of the fire-extinguishing system referred to in subsection (1) or (2) shall be provided at each access to every space served by that system and at the control station.
(10) Every installation provided with a fire-extinguishing system referred to in subsection (1) or (2) shall be provided with an automatic system that will give
(a) an audible warning, in every space served by that system to which personnel have access, before the fire extinguishing medium is released from the fire extinguishing system; and
(b) an audible and visual signal, outside the access to every space served by that system and at the fire and gas indicator panel in the control station, when the fire extinguishing system is in operation.
(11) Every installation provided with a fire-extinguishing system referred to in subsection (1) or (2) shall be provided with means to close all openings that may admit air to or allow gas to escape from a space served by that system.
Fire extinguishers
29 (1) On every installation a portable fire extinguisher shall be provided(a) within 10 m of any position accessible by personnel in every machinery, drilling and production and process space;
(b) within 15 m of any position accessible by personnel in every space other than a space described in clause (a); and
(c) near the entrance to each space referred to in clauses (a) and (b).
(2) Subject to subsection (3), the extinguishing medium employed by an extinguisher provided pursuant to subsection (1) shall be suitable for extinguishing fires in spaces in which it is intended to be used.
(3) Each extinguisher provided pursuant to subsection (1) for use in machinery spaces where oil is used as fuel shall be of a type discharging foam, carbon dioxide gas or dry powder.
(4) The capacity of each portable extinguisher provided pursuant to this Section shall be at least
(a) 9 L, for an extinguisher that discharges foam;
(b) 4.5 kg, for an extinguisher that discharges dry powder;
(c) 6 kg, for an extinguisher that discharges carbon dioxide gas; and
(d) 9 L, for an extinguisher that discharges water.
(5) A spare charge shall be provided for each portable extinguisher provided pursuant to this Section for which a duplicate extinguisher has not been provided.
(6) On an installation, every space containing internal combustion machinery that has an aggregate power of at least 750 kW shall be provided with one portable foam applicator unit and the following fire extinguishers:
(a) one foam type fire extinguisher of not less than 45 L capacity in every engine space;
(b) two portable foam extinguishers, where the aggregate power of the machinery is at least 750 kW but not more than 1500 kW;
(c) three portable foam extinguishers, where the aggregate power of the machinery is more than 1500 kW but not more than 2250 kW;
(d) four portable foam extinguishers, where the aggregate power of the machinery is more than 2250 kW but not more than 3000 kW;
(e) five portable foam extinguishers, where the aggregate power of the machinery is more than 3000 kW but not more than 3750 kW; and
(f) six portable foam extinguishers, where the aggregate power of the machinery is more than 3750 kW.
(7) On an installation, every space containing an oil- or gas-fired boiler or any other fired process vessel that has a thermal rating of at least 75 kW shall be provided with
(a) two portable foam fire extinguishers plus an additional portable foam fire extinguisher for each burner up to a total capacity of 45 L;
(b) one portable dry powder fire extinguisher; and
(c) one portable foam applicator unit.
(8) Every portable foam applicator unit provided pursuant to this Section shall be provided with
(a) an air-foam nozzle of an inductor type capable of being connected to the water main described in subsection 24(2) and of producing foam effective for extinguishing an oil fire at the rate of at least 1.5 m3/minute; and
(b) at least two tanks, each containing at least 20 L of foam-making liquid.
(9) Every portable fire extinguisher on an installation shall be inspected, maintained and recharged in accordance with National Fire Protection Association 10, Standard for Portable Fire Extinguishers.
Firefighting equipment
30 (1) Every manned installation shall be provided with at least ten sets of firefighter equipment and every unmanned installation shall be provided with at least two sets of firefighter equipment, each of which shall consist of(a) protective clothing, including boots and gloves, that
(i) meets the requirements of National Fire Protection Association 1971, Standard on Protective Clothing for Structural Fire Fighting,
(ii) will protect the skin from being burned by heat radiating from a fire and by steam,
(iii) has a water-resistant outer surface,
(iv) in the case of boots, is made of rubber or other electrically non-conducting material, and
(v) in the case of gloves, meets the requirements of National Fire Protection Association 1973, Standard on Gloves for Structural Fire Fighting; and
(b) a firefighter's helmet with visor that meets the requirements of Canadian Standards Association CAN/CSA-Z94.1-92, Industrial Protective Headwear.
(2) In addition to any firefighting equipment required by the Nova Scotia Offshore Area Oil and Gas Occupational Safety and Health Regulations, every manned installation shall be provided with at least four sets, and every unmanned installation shall be provided with at least two sets, of the following equipment:
(a) a self-contained breathing apparatus that
(i) is capable of functioning for at least 30 minutes,
(ii) meets the requirements of Canadian Standards Association CAN/CSA-Z94.49-3, Selection, Use, and Care of Respirators, and CAN3-Z 180.1-M85, Compressed Breathing Air and Systems, and
(iii) is equipped with two spare bottles;
(b) a portable electric safety lamp that
(i) will operate in the conditions anticipated for a Class I, Division 1, hazardous area,
(ii) is operated from a rechargeable battery capable of operating for at least 3 hours, and
(iii) can be easily attached to the clothing of a firefighter, at or above the waist level;
(c) an axe with an insulated handle and a carrying belt; and
(d) a fire-resistant life and signalling line and a safety belt and harness that meet the requirements of National Fire Protection Association 1983, Standard on Fire Service Life Safety Rope, Harness and Hardware.
(3) Each set of equipment required by subsections (1) and (2) shall be kept ready for use and stored so as to be readily accessible.
(4) One of each of the sets of equipment required by subsections (1) and (2) shall be located within easy access of the helicopter deck.
Automatic fire detection systems
31 (1) Every manned installation shall be equipped with a fire detection system that is capable of detecting the presence of fire in every space where fire may occur, including(a) every corridor, stairway and escape route in the accommodation areas;
(b) the control station;
(c) every work area; and
(d) every space containing equipment in which petroleum or any other flammable substance is stored, conveyed, processed or consumed.
(2) Every unmanned installation shall be equipped with a fire detection system that is capable of detecting the presence of fire in every space where fire may occur, including
(a) every work area; and
(b) every space containing equipment in which petroleum or any other flammable substance is stored, conveyed, processed or consumed.
(3) Every fire detection system required by subsections (1) and (2) shall be selected, designed, installed and maintained in accordance with National Fire Prevention Association 72E, Standard on Automatic Fire Detectors.
(4) The fire detection systems required by subsections (1) and (2) shall, on detection of fire, activate automatically
(a) an audible and visual signal on the fire and gas indicator panel in the control station of a manned installation; and
(b) an audible alarm that has a tone different from any other alarm in any part of the installation.
Gas detection systems
32 (1) Every installation shall be equipped with a gas detection system that is capable of detecting, in every part of the installation in which hydrogen sulphide or any type of hydrocarbon gas may accumulate, the presence of those gases.(2) The gas detection system required by subsection (1) shall, on detection of gas, activate automatically
(a) an audible and visual signal on the fire and gas indicator panel in the control station of a manned installation; and
(b) an audible alarm that has a tone different from any other alarm in any part of the installation.
(3) Every installation shall be equipped with
(a) at least two portable gas detectors capable of
(i) measuring the concentration of oxygen in any space, and
(ii) detecting hydrogen sulphide and any type of hydrocarbon gas in any space; and
(b) a means of testing the portable gas detectors described in clause (a).
(4) A gas detector shall be provided
(a) at every ventilation inlet duct leading to a non-hazardous area on every installation; and
(b) in every enclosed hazardous area on every installation.
(5) Every gas detector provided in accordance with subsection (3) shall be appropriate for the area and installed and operated in accordance with
(a) Appendix C of American Petroleum Institute RP 14C, Recommended Practice for Analysis, Design, Installation and Testing of Basic Surface Safety Systems for Offshore Production Platforms; and
(b) Section 9.2 of American Petroleum Institute RP 14F, Recommended Practice for Design and Installation of Electrical Systems for Offshore Production Platforms.
Alarm panels and signals
33 (1) Every manned installation shall be equipped with a fire or gas detection system that includes(a) one or more fire and gas detector indicator panels located at the control station, that
(i) indicate the source of fire and gas by means of a visual signal,
(ii) are capable of being functionally tested, and
(iii) are fitted with equipment for resetting the fire and gas detection systems; and
(b) an audible fire and gas alarm that has a characteristic tone that distinguishes it from the alarms associated with machinery, safety and control system faults or any other alarm system and that is audible on all parts of the installation.
(2) A fire or gas detection system referred to in subsection (1) shall
(a) be capable of being manually activated from each of the following locations, namely,
(i) the space adjacent to each entrance to each machinery and process space,
(ii) each accommodation area,
(iii) the office of the manager of the installation,
(iv) every control point in each machinery and process space, and
(v) the control station;
(b) be designed so that, on activation of a detection device in one space, any signals received at the same time from a detection device in another space will register at the fire and gas indicator panel at that same time;
(c) be installed and maintained in accordance with National Fire Prevention Association 72, Standard for the Installation, Maintenance, and Use of Protective Signaling Systems; and
(d) be arranged so that there will be an automatic changeover to an emergency source of electrical power in accordance with subsection 12(7) in the event of a failure of the primary source of electrical power and so that failure of the primary source of electrical power will be indicated both visually and audibly as a separate fault alarm.
General alarm system
34 (1) Every installation shall be equipped with a general alarm system that is capable of alerting personnel to any hazardous conditions other than fire or gas that might(a) endanger the personnel;
(b) endanger the installation; or
(c) be harmful to the environment.
(2) Every general alarm system referred to in subsection (1) shall be
(a) operational and in operation at all times other than when the system is being inspected, maintained or repaired;
(b) where applicable, flagged as being subject to inspection, maintenance or repair; and
(c) designed in such a manner as to prevent tampering.
(3) Where a general alarm system for an installation is being inspected, maintained or repaired, the operator of the installation shall ensure that the functions that the system performs are performed manually.
Piping systems
35 (1) The piping system and associated equipment of every installation shall be designed and installed in accordance with American Petroleum Institute RP 14E, Recommended Practice for Design and Installation of Offshore Production Platform Piping Systems.(2) Every pressure vessel or fired vessel on a production installation shall be designed and constructed in accordance with the following standards:
(a) American Petroleum Institute Spec 12J, Specification for Oil and Gas Separators;
(b) Sections I, II, IV, V, VII, VIII and IX of American Society of Mechanical Engineers ASME Boiler & Pressure Vessel Code; and
(c) Canadian Standards Association B51-M1991, Boiler, Pressure Vessel, and Pressure Piping Code.
(3) Every compressor in hydrocarbon service at a production installation shall be designed in accordance with the following standards:
(a) Canadian Standards Association CAN/CSA-Z184-92, Gas Pipeline Systems;
(b) American Petroleum Institute STD 617, Centrifugal Compressors for General Refinery Service;
(c) American Petroleum Institute STD 618, Reciprocating Compressors for General Refinery Services; and
(d) American Petroleum Institute STD 619, Rotary-Type Positive Displacement Compressors for General Refinery Services.
(4) All materials and procedures used in a production installation used to produce and process sour gas shall conform to National Association of Corrosion Engineers (U.S.) MR-01-75, Sulfide Stress Cracking Resistant Metallic Materials for Oil Field Equipment.
(5) Where an operator handles, treats or processes oil, gas or water that contains hydrogen sulphide, the operator shall do so in accordance with good industry practice to minimize the discharge of hydrogen sulphide into the environment and to ensure that the operation is carried out in a safe and efficient manner.
Communication systems
36 (1) No person shall operate a manned installation unless the installation is equipped with(a) a radio or telephone communication system; and
(b) an emergency communication system.
(2) The communication systems referred to in subsection (1) shall be operational at all times.
(3) No person shall operate a manned installation unless the installation is equipped with a two-way radio communication system that
(a) enables effective communication by radio to be maintained between the installation and helicopters, the shore base, support vessels, standby vessels, search and rescue aircraft, and other nearby installations; and
(b) enables effective communication with marine traffic in the vicinity.
(4) The operator of a manned installation shall ensure that the radio communication systems comply with the Ship Station Radio Regulations (Canada) and the Ship Station Technical Regulations (Canada), as if the installation were a ship to which those regulations apply.
(5) Each installation shall comply with the VHF Radiotelephone Practices and Procedures Regulations (Canada), as if the installation were a ship to which those regulations apply.
(6) No person shall operate a manned installation unless the installation is equipped with
(a) an internal telephone system;
(b) a public address system with loudspeakers located so that a voice transmission can be heard throughout the installation; and
(c) a means of transmitting written data to the shore base of the installation.
(7) No person shall operate an installation that is usually unmanned unless the installation is equipped with
(a) an operational two-way radio communication system during any period when the installation is manned; and
(b) a system capable of detecting under ambient conditions any hazardous conditions that could endanger the safety of the installation or damage the environment and of alerting the control station about the hazardous conditions.
Part II - Analysis and Design
General design considerations
37 (1) Every installation and every component of an installation shall be designed in accordance with good engineering practice, taking into account(a) the nature of the activities on and around the installation;
(b) the type and magnitude of functional loads, environmental loads, and foreseeable accidental loads;
(c) operating and ambient temperatures;
(d) corrosion conditions that may be encountered during the construction, operation and maintenance of the installation;
(e) the avoidance of damage to any part of the installation that may lead to the progressive collapse of the whole installation; and
(f) soil conditions.
(2) The design of an installation shall be based on such analyses or model tests of the installation, including simulations to the extent practicable, as are necessary to permit the determination of the behaviour of the installation and of the soils that support the installation or anchoring systems, under all foreseeable transportation, installation and operating conditions.
Design of installations
38 Every installation shall be designed in accordance with(a) Section 4 of Canadian Standards Association CAN/CSA-S471-92, General Requirements, Design Criteria, the Environment, and Loads;
(b) for the foundation, Section 5 of Canadian Standards Association CAN/CSA-S472-92, Foundations, Offshore Structures;
(c) for a steel platform, Section 7 of Canadian Standards Association CAN/CSA-S473-92, Steel Structures, Offshore Structures;
(d) for a concrete platform, Sections 3 and 7 of Canadian Standards Association Preliminary Standard S474-M1989, Concrete Structures; and
(e) in respect of its transportation and installation, Sections 5, 6 and 7 of Canadian Standards Association Preliminary Standard S475-M1989, Sea Operations.
Design of platforms
39 Every platform shall be designed in accordance with(a) for composite ice-resisting walls, Section 13 of Canadian Standards Association CAN/CSA-S473-92, Steel Structures, Offshore Structures;
(b) for the foundation, Section 5 of Canadian Standards Association CAN/CSA-S472-92, Foundations, Offshore Structures;
(c) for a steel platform, Sections 9, 10, 11, 12 and 16 of Canadian Standards Association CAN/CSA-S473-92, Steel Structures, Offshore Structures<